1) Uplift loads have been increased 60% for wind or seismic loads; no further increase shall be permitted.
2) H
eff is the minimum distance from the top of the hanger seat to the top of the carrying member.
3) For tabulated top-mount installation loads, the straps must be wrapped over the header a minimum of 2".