SHARE:  

Accucraft Newsletter

6/21/2017 

Safe Operation Instructions for 1:13.7 scale Decauville Type 1 0-4-0T

The information below is found in the Decauville Owner’s Manual, however, we are again reiterating several key points to communicate the successful firing and operation of your locomotive. Note this loco is small in overall size and requires paying careful attention. 

Lighting up

Be sure the throttle is closed and the Johnson bar is in neutral. Open thsmokebox door and slightly open the gas valve. Using a stick lighter brinthe flame to the smokebox door and light the gas. The burner should lighand pop back into the flue. Be sure the fire is not in the smokebox! Check the flame and make sure it is a strong blue flame. If yellow or green, adjusthe air collar on the burner flange in the cab.

IMPORTANT
-
 Fire should be at the lowest possible setting while maintaining steam
- Ensure the fire is in the flue and NOT the smokebo
x


If fire is not in the flue and remains in smokebox:
- Check the jets are clean, clean jets if necessary
- Burner 
must be straight and parallel to the flue
!

Once the pressure is up to 50-60psi the safety valve should lift and you arready to run and clear the cylinders. Reverse works best for this as thboiler surges water away from the throttle takeoff. Water and oil wileject from the chimney, a cloth or towel will help deflect and keep thloco clean. Once the cylinders are warm and cleared of condensate yoare ready to set the locomotive off onto the main line.

Adjust the burner level to suit the running conditions and keep as low as possible while maintaining the needed steam supply. Excessive blowinof the safety is wasting fuel and water and shortens the run time.Maintain the boiler level using an optional Goodall Valve. Never allothe water level to get below the top of the burner as that exposes the flufrom water inside the boiler.

Additional information

Accucraft is currently preparing a kit featuring additional insulation for installation in the smokebox and gas tank. The kit will be available at no charge to Decauville owners in three weeks.


And the post used for communicating replacement fuel tanks:

For owners of our recently delivered 7/8ths scale Decauville Type 1 0-4-0T, we will soon make available a retrofit slimmer, fully insulated butane gas tank for your loco. If you require a replacement tank please contact your dealer or us directly. 

At present we're mailing out the retrofit insulation kits for these locomotives. Decauville owners should be receiving theirs shortly. 
Accucraft reserves the right to change prices, colors, specifications and availability  without  notice.
All items are FOB Union City, CA.
Accucraft Trains
33268 Central Ave, Union City, CA 94587
510-324-3399 • www.accucraft.com • info@accucraftestore.com