MiTechnology is designed for greater technical visibility - to offer you the latest and most relevant of MiTek's technical information and specifications. For builders, design professionals, suppliers, building inspectors: this bulletin will keep you current and give you quick access to additional information and support documents. It will also link you to the full range of resources we offer you on our website, or through our customer support team.
Fire Wall Hangers
FWH series
The Fire Wall Hanger is designed for attaching truss, I-joist, solid sawn lumber, or engineered wood floor framing members to double wall top plates or minimum 2-ply 2x solid sawn header fire rated wood frame walls. The advanced design allows the installation of the FWH before the 5/8" gypsum wallboard (drywall) is attached and permits the building project to be completely framed-up, and weather-tight before the gypsum wallboard sheathing work starts.
fig1


FEATURES:
* Hangers can be installed before gypsum wallboard
  is attached
* Code Evaluated
* 2-hour tested fire rating per ASTM E814
* No additional connectors required to prevent top
  plate  rotation typical of other fire wall hangers.
* Skewed Specialty Option up to 45°

Materials: 14 gauge

Finish: G90 galvanizing


Codes: ICC-ES ESR-3444, 
Patents: Pending


Installation:
* Install the face of hanger flanges tight to stud wall framing.

* For wall framing, hangers do NOT need to be installed  at stud locations for full design values.

* The end of the truss/joist should measure 1-5/8" from the  face of the supporting wall. See Figure 1.

* The truss/joist should bear fully on the FWH seat with a gap no greater than 1/8" between  the end of the supported member and the hanger.
See Figure 1.

* Gypsum Wallboard Installation - Use the FWH-T template to slot cut the gypsum wallboard.  See FWH-T Template Installation Sequence below. Slide the gypsum wallboard into position  and fasten to the framing members meeting minimum requirements specified by code.
2-Hour Fire-Rating
FWH hangers are tested per ASTM E814 standards. When installed on one side of a maximum 2 hour fire-rated wall assembly, the penetration of the USP FWH Fire Wall Hanger through the gypsum wallboard will not reduce the fire resistive rating of the 2 hour fire resistive assembly.
Fastener / Allowable Load Table
           Geometry Table
template
SOC