Application Rate Requirement: 10 gpa
Droplet Size Requirement: Course (C) and Extra Course (XC)
Nozzles Selected:
- Nozzle A: ULD120-02
- Nozzle B: ULD120-03
- Nozzle A+B: ULD120-02 & ULD120-03
(equivalent flow of an 05 nozzle)
Switching Set Points:
- A to B Set Point: 7 mph
- A+B Set Point: 10.5 mph
Allows for travel speeds: 4 mph - 18 mph
|